 XH-M452 Digital Temperature Humidity Controller

Best Online Shopping website for XH-M452 Digital Temperature Humidity Controller thermostat.
Simple panel control, wide temperature range, simple design, elegant appearance, high mechanical strength. It can be embedded industrial equipment, convenient and fast. It can be used for hatch control, equipment cabinet, air conditioning system, temperature control protection, etc.

Features:

  1. Supports heating mode and cooling mode.
  2. High precision 0.1 Celsius and 0.1% RH.
  3. Real-time display of temperature and humidity.
  4. Custom load, arbitrarily selected.
  5. Simple setting.
  6. Easy installation.
  7. Power-down memory function.

Parameters:

NO.PARAMETERVALUE
1ModeXH-M452
2Input voltageDC 12V
3Temperature range-20~60 Celsius
4Humidity range00%-100% RH
5Detection accuracy0.1 Celsius 0.1% RH
6Detection accuracy0.1 Celsius
7Sensor1 Meter Temperature and humidity sensor
8Output TypeRelay Output (Switch Output)
9Size65x55x28mm

Key Description:

  • ‘Temperature +’ : Short press to display start temperature; Long press to set start temperature by key ‘Temperature +’ and ‘Temperature -’ and display will flashing. It will save automatically after 5 Seconds. (Long press is for 3 seconds).
  • ‘Temperature -’ : Short press to display stop temperature; Long press to set stop temperature by key ‘Temperature +’ and ‘Temperature -’ and display will flashing. It will save automatically after 5 Seconds. (Long press is for 3 seconds).
  • ‘Humidity +’ : Short press to display start humidity; Long press to set start humidity by key ‘Humidity +’ and ‘Humidity -’ and display will flashing. It will save automatically after 5 Seconds. (Long press is for 3 seconds).
  • ‘Humidity -’ : Short press to display stop humidity; Long press to set stop humidity by key ‘Humidity +’ and ‘Humidity -’ and display will flashing. It will save automatically after 5 seconds. (Long press is for 3 seconds).
  • Note: Restore factory settings if keep press ‘Temperature -’ and ‘Humidity +’ until two screen flashing and display ‘888 888’ at the time.

Temperature Control:

  • Set Start Temperature: Long press ‘Temperature +’ to set start temperature by key ‘Temperature +’ and ‘Temperature -’ and display will flashing. It will save automatically after 5 seconds and then display current actual temperature.
  • Set Stop Temperature: Long press ‘Temperature -’ to set stop temperature by key ‘Temperature +’ and ‘Temperature -’ and display will flashing. It will save automatically after 5 seconds and then display current actual temperature.
  • Automatic mode selection:

It is Heating mode if Start Temperature is lower than Stop Temperature. It is Cooling mode if Start Temperature is higher than Stop Temperature.

  • Set Steps: Focus: Start Temp < Stop Temp (Heating mode, Automatic judgment)

Start Temp > Stop Temp (Cooling mode, Automatic judgment)

Method: Please refer to Set Start/Stop Temperature.

Heating mode example: Control water heater. Heated to 65 Celsius and then stop heating. Reheat when the temperature drops to 50Celsius.

Step 1 : Set Heating mode, Start Temp < Stop Temp.

Step 2 : Long press ‘Temperature +’ and Start Temp flashing. Set Start Temperature to 50 Celsius by ‘Temperature +’ and ‘Temperature -’.

Step 3 : Long press ‘Temperature -’ and Stop Temp flashing.Set Stop Temperature to 65Celsius by ‘Temperature +’ and ‘Temperature -’.

Cooling mode example: Control farms. Stop ventilation when temperature is 26 Celsius. Refrigeration again when the temperature rises to 30 Celsius.

Step 1 : Set Cooling mode, Start Temp > Stop Temp.

Step 2 : Long press ‘Temperature +’ and Start Temp flashing. Set Start Temperature to 30 Celsius by ‘Temperature +’ and ‘Temperature -’.

Step 3 : Long press ‘Temperature -’ and Stop Temp flashing. Set Stop Temperature to 26Celsius by ‘Temperature +’ and ‘Temperature -’.

NOTE: Indicator will OFF and Load will not work If the temperature is set incorrectly. So please check if Start Temp and Stop Temp are right after set.

Humidity Control:

  • Set Start Humidity : Long press ‘Humidity+’ to set start humidity by key ‘Humidity+’ and ‘Humidity-’ and display will flashing. It will save automatically after 5 seconds and then display current actual humidity .
  • Set Stop Humidity : Long press ‘Humidity-’ to set stop humidity by key ‘Humidity+’ and ‘Humidity-’ and display will flashing. It will save automatically after 5 seconds and then display current actual humidity .
  • Automatic mode selection : It is Humidification mode if Start Humidity is lower than Stop Humidity.

It is Dehumidify mode if Start Humidity is higher than Stop Humidity.

  • Humidification mode example: Fresh storage humidification, control humidifier 50% RH to begin humidification, humidify to 80% RH stop.

Step 1 : Set Humidification mode, Start Hum< Stop Hum.

Step 2 : Long press ‘Humidity+’ and Start Hum flashing. Set Start Humidity to 50% RH by ‘Humidity+’ and ‘Humidity-’.

Step 3 : Long press ‘Humidity-’ and Stop Hum flashing. Set Stop Humidity to 80% RH by ‘Humidity+’ and ‘Humidity-’.

  • Dehumidify mode example: Dehumidification control system in the workshop, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification. Step 1 : Set Humidification mode, Start Hum> Stop Hum.

Step 2 : Long press ‘Humidity+’ and Start Hum flashing. Set Start Humidity to 70% RH by ‘Humidity+’ and ‘Humidity-’.

Step 3 : Long press ‘Humidity-’ and Stop Hum flashing. Set Stop Humidity to 40% RH by ‘Humidity+’ and ‘Humidity-’.

Application:

  1. Hatch control
  2. Equipment cabinet
  3. Air conditioning system
  4. Temperature control protection
  5. Refrigerator
  6. Freezer
  7. Water heater
  8. Hosts
  9. Printing factory
  10. Tobacco industry
  11. Hatchery control

Package Include:

1 x XH-M452 Digital Temperature Humidity Controller

Restore factory settings if keep press ‘Temperature -’ and ‘Humidity +’ until two screen flashing and display ‘888 888’ at the time.It is Heating mode if Start Temperature is lower than Stop Temperature. It is Cooling mode if Start Temperature is higher than Stop Temperature.It will save automatically after 5 seconds and then display current actual temperature.save automatically after 5 seconds and then display current actual humidity .Automatic mode selection : It is Humidification mode if Start Humidity is lower than Stop Humidity.It is Dehumidify mode if Start Humidity is higher than Stop Humidity..It is Heating mode if Start Temperature is lower than Stop Temperature.Stop ventilation when temperature is 26 Celsius. Refrigeration again when the temperature rises to 30 Celsius.Stop ventilation when temperature is 26 Celsius. Refrigeration again when the temperature rises to 30 Celsius. So please check if Start Temp and Stop Temp are right after set.
So please check if Start Temp and Stop Temp are right after set.
It will save automatically after 5 seconds and then display current actual temperature.It will save automatically after 5 seconds and then display current actual temperature.
It will save automatically after 5 seconds and then display current actual temperature.It will save automatically after 5 seconds and then display current actual temperature.
So please check if Start Temp and Stop Temp are right after set.
It will save automatically after 5 seconds and then display current actual temperature.It will save automatically after 5 seconds and then display current actual temperatureIt will save automatically after 5 seconds and then display current actual temperature.It will save automatically after 5 seconds and then display current actual temperature.