{"product_id":"et8102-digital-multimeter-6000-counts-true-rms-flashlight-digital-voltmeter-1000v-10a-ac-dc-ammeter-pocket-multimeter-in-pakistan","title":"ET8102 Digital Multimeter 6000 Counts True RMS Flashlight Digital Voltmeter 1000V 10A AC\/DC Ammeter Pocket Multimeter in Pakistan","description":"\u003ch3 id=\"description\" class=\"tab-list-title\"\u003eDescription\u003c\/h3\u003e\n\u003cdiv id=\"content_description\" class=\"ty-wysiwyg-content content-description\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eFunctions\u003c\/p\u003e\n\u003cp\u003eButtons:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelect (Yellow): Select DC\/AC in current modes, continuity, diode, capacity, temperature in ohm mode and can also be used to show duty cycle in Hz mode and frequency and duty cycle in AC mode.\u003c\/li\u003e\n\u003cli\u003eHold: Will freeze the display reading, until pressed again, hold down to activate the background light.\u003c\/li\u003e\n\u003cli\u003eRange, REL: Select manual range and change range, hold down to reactivate automatic ranging. In capacitance it is a REL function to zero out and offset.\u003c\/li\u003e\n\u003cli\u003eMax\/min: Capture maximum and minimum values, it will change between max\/min\/actual, holding it down will activate flashlight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRotary switch:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOff: Meter is turned off\u003c\/li\u003e\n\u003cli\u003eVAC: AC voltage and frequency\/duty-cycle, the frequency input has high sensitivity and low bandwidth.\u003c\/li\u003e\n\u003cli\u003eVDC: DC voltage\u003c\/li\u003e\n\u003cli\u003eOhm, diode, continuity, capacitance, temperature Fahrenheit, temperature Celsius\u003c\/li\u003e\n\u003cli\u003eHz: Logical frequency input, can also show duty cycle.\u003c\/li\u003e\n\u003cli\u003eA: Ampere DC or AC\u003c\/li\u003e\n\u003cli\u003emA: Milli ampere DC or AC\u003c\/li\u003e\n\u003cli\u003euA: Micro ampere DC or AC\u003c\/li\u003e\n\u003cli\u003eTest: Phase detection with one connection. This will show 0 or OL in the display, OL means phase detected.\u003c\/li\u003e\n\u003cli\u003eNCV: Non-contact voltage or electric field detection.\u003c\/li\u003e\n\u003cli\u003e10ADC: 10A DC current input.\u003c\/li\u003e\n\u003cli\u003eCOM: The common terminal for all ranges.\u003c\/li\u003e\n\u003cli\u003exxx: All other ranges, including uA and mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMeasurements\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVolt and frequency\n\u003cul\u003e\n\u003cli\u003e1V AC readings is 5% down at 2.3kHz, rms will not work at that frequency\u003c\/li\u003e\n\u003cli\u003eAC frequency range with 0.1V input is from 1.1Hz to 2.5kHz\u003c\/li\u003e\n\u003cli\u003eAC frequency range with 0.1V input it can be stretched to 32kHz\u003c\/li\u003e\n\u003cli\u003eAC frequency range requires a zero crossing.\u003c\/li\u003e\n\u003cli\u003eFrequency input can handle +\/-2.8V offset with 1Vrms input.\u003c\/li\u003e\n\u003cli\u003eAt 1Vrms frequency input range is from 1.1Hz to 44MHz\u003c\/li\u003e\n\u003cli\u003eDuty cycle works from 1% to 99% at 100kHz with 4Vpp, precision is within 0.3.\u003c\/li\u003e\n\u003cli\u003eMax\/min needs about 200ms to capture a voltage, autorange is disabled when using this function and it will not capture every max\/min.\u003c\/li\u003e\n\u003cli\u003eInput impedance is 10-11Mohm on DC and AC\u003c\/li\u003e\n\u003cli\u003eFrequency input is 2-3kOhm in input impedance above 2V\u003c\/li\u003e\n\u003cli\u003eInput protection is 1000VDC\/750VAC\u003c\/li\u003e\n\u003cli\u003eFrequency input is protected to 250V or 550V DC or AC peak (Both values are specified).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCurrent\n\u003cul\u003e\n\u003cli\u003e10A range has audible alarm above 10A\u003c\/li\u003e\n\u003cli\u003e10A range is fused with a 10A\/250V 5×20mm fuse\u003c\/li\u003e\n\u003cli\u003emAuA range is fused with a 0.6A\/250V 5×20mm fuse\u003c\/li\u003e\n\u003cli\u003eCurrent ranges starts in DC\u003c\/li\u003e\n\u003cli\u003eInput voltage must not be more than 36VDC or 25VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOhm, continuity, diode and capacitance\n\u003cul\u003e\n\u003cli\u003eOhm needs about 2.5s to measure 100ohm\u003c\/li\u003e\n\u003cli\u003eOhm voltage is 1.1V open and 0.25mA shorted.\u003c\/li\u003e\n\u003cli\u003eContinuity is fast (About 20ms).\u003c\/li\u003e\n\u003cli\u003eContinuity beeps when resistance is below 50ohm.\u003c\/li\u003e\n\u003cli\u003eContinuity is 2.1V open and 0.25mA shorted\u003c\/li\u003e\n\u003cli\u003eDiode range uses 4.0V, max. display is 3.3V at 0.25mA, max. current is 1.5mA shorted\u003c\/li\u003e\n\u003cli\u003e10uF takes about 2.5 seconds to measure.\u003c\/li\u003e\n\u003cli\u003e70000uF takes about 7 seconds to measure.\u003c\/li\u003e\n\u003cli\u003eOverload protection is 550V DC or AC peak\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMiscellaneous\n\u003cul\u003e\n\u003cli\u003eCurrent consumption of meter is 1.6mA, 8.2mA with backlight, 9.1mA with backlight and 13.3mA with both.\u003c\/li\u003e\n\u003cli\u003eMeter turns off at 2.2V, battery symbol show at 2.3V.\u003c\/li\u003e\n\u003cli\u003eReadings will be correct until meter turns off.\u003c\/li\u003e\n\u003cli\u003eBacklight fades with dropping voltage, but it usable until meter turns off.\u003c\/li\u003e\n\u003cli\u003eFlashlight fades with dropping voltage, but it usable until meter turns off.\u003c\/li\u003e\n\u003cli\u003eViewing angle is good except from the top.\u003c\/li\u003e\n\u003cli\u003eDisplay updates around 3 times\/sec\u003c\/li\u003e\n\u003cli\u003eBacklight will automatic turn off after about 12 seconds.\u003c\/li\u003e\n\u003cli\u003eFlashlight will not automatic turn off, but turns off when the meter turns off.\u003c\/li\u003e\n\u003cli\u003eWill automatic turn power off in about 17 minutes.\u003c\/li\u003e\n\u003cli\u003eStandard probes cannot be fully seated in the meter, but they do connect (About 5mm stick up).\u003c\/li\u003e\n\u003cli\u003eThe meter usual need a few display update to before it display the value.\u003c\/li\u003e\n\u003cli\u003eWeight is 209g without accessories, but with sleeve and battery.\u003c\/li\u003e\n\u003cli\u003eSize is 145 × 70 × 37mm with sleeve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProbes\n\u003cul\u003e\n\u003cli\u003eProbe resistance 46mOhm for one.\u003c\/li\u003e\n\u003cli\u003eProbe wire is soft and 73cm long.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Electronics Hub","offers":[{"title":"Default Title","offer_id":54466885976377,"sku":"product-6634","price":3050.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0965\/3623\/2249\/files\/kjnm-1-1.webp?v=1789237453","url":"https:\/\/electronicshub.pk\/products\/et8102-digital-multimeter-6000-counts-true-rms-flashlight-digital-voltmeter-1000v-10a-ac-dc-ammeter-pocket-multimeter-in-pakistan","provider":"Electronics Hub","version":"1.0","type":"link"}