Description

Description

The Fluke 17B+ digital multimeter does all that and more. Common basic electrical measurements plus temperature, frequency and duty cycle. Easy to use with one hand, even with gloves on, the Fluke 17B+ offers everything you need.

Key features

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Over-voltage indicator
  • Frequency and temperature measurement
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. These specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function Range Resolution Accuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5% + 3.0
.5% + 2
0.5% + 2.0
.5% + 2
0.5% + 2.0
1.5% + 3

Capacitance

Capacitance3

40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2% + 5
2% + 5.0
5.0% + 5
5% + 5.0
5.0% + 5
5% + 5
Frequency1 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1% + 3
Duty Cycle1 1% to 99% 0.1% 1% typical 4
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
Temperature 50 °C- 400 °C
0 °C- 50 °C
-55 °C- 0 °C
0.1C 2% ±1 °C
±2 °C
9% ±2 °C
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90%.

More Information:
Function Overload protection Input impedance (Nominal) Common mode rejection ratio Normal mode rejection ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
1 106 V Hz Max

 

Packages Include:

1 × MULTIMETER 17B+ FLUKE

Additional information

Weight 0.1 kg

Reviews

There are no reviews yet.

Be the first to review “MULTIMETER 17B+ FLUKE In Pakistan”

Your email address will not be published. Required fields are marked *

17 − eleven =